Functions | |
void | fwSpecs_clear () |
void | fwSpecs_get (dyn_string &pSPECSList) |
bool | fwSpecs_add (string pSPECS) |
bool | fwSpecs_remove (string pSPECS) |
bool | fwSpecs_getMasterIDs (string pSPECS, dyn_int &pMasterIDsList) |
bool | fwSpecs_getMasterCardsInfo (string pSPECS, dyn_int &pMasterCardsPCIList, dyn_dyn_int &pMasterCardsDateList) |
bool | fwSpecs_setClockFrequency (string pSPECS, int pMasterID, int pClockFrequency) |
int | fwSpecs_resetMaster (string pSPECS, int pMasterID, int hardResetFlag=0) |
int | fwSpecs_resetSlave (string pSPECS, int pMasterID, int pSlaveAddress, int pMode) |
int | fwSpecs_slaveLeds (string pSPECS, int pMasterID, int pSlaveAddress, int pMode) |
bool | fwSpecs_saveScript (string pScriptName, string pScript="") |
bool | fwSpecs_removeScript (string pScriptName) |
bool | fwSpecs_getScripts (dyn_dyn_string &pScriptsList) |
bool | fwSpecs_executeScript (string pScriptName, dyn_string pParametersList=makeDynString()) |
bool | fwSpecs_removeRegisters (dyn_string pRegistersList) |
bool | fwSpecs_getRegisters (dyn_dyn_string &pRegistersList, int pRegisterType=-1) |
bool fwSpecs_add | ( | string | pSPECS | ) |
This function adds the specified SPECS and, also, subscribes all the DIM services & commands that are needed to communicate with that SPECS. Note: this function just needs to be called once and only once for every new SPECS.
[in] | pSPECS | name of the SPECS to be added. |
false error found.
(...) if (fwSpecs_add("pclbcecs03")) // add the SPECS 'pclbcecs03' (...) else DebugTN("Error found!"); (...)
void fwSpecs_clear | ( | ) |
This function clears the entire system (datapoints will be removed and all the DIM services & commands will be unsubscribed). This function should be used with EXTREME CAUTION, since all data will be LOST.
(...) fwSpecs_clear(); // clear the entire system DebugTN("The system is clear!"); (...)
bool fwSpecs_executeScript | ( | string | pScriptName, | |
dyn_string | pParametersList = makeDynString() | |||
) |
This function executes the specified script.
[in] | pScriptName | name of the script to be executed. |
[in] | pParametersList | list of parameters to be passed to the main function of the script. Note: this parameter is optional (if not specified, then an empty parameters list will be passed). |
false error found.
(...) if (fwSpecs_executeScript("myScript")) // execute the script 'myScript' with no parameters (...) else DebugTN("Error found!"); (...)
void fwSpecs_get | ( | dyn_string & | pSPECSList | ) |
This function returns a list of SPECS servers running in the moment. If there is no SPECS server running, then the returned list will be empty.
[out] | pSPECSList | list containing the SPECS server running in the moment. |
(...) dyn_string myList; int i; fwSpecs_get(myList); // get a list of SPECS servers running in the moment DebugTN("SPECS servers: " + dynlen(myList)); // display number of SPECS servers running in the moment for(i = 1; i <= dynlen(myList); i++) DebugTN(myList[i]); (...)
bool fwSpecs_getMasterCardsInfo | ( | string | pSPECS, | |
dyn_int & | pMasterCardsPCIList, | |||
dyn_dyn_int & | pMasterCardsDateList | |||
) |
This function returns information about the master card(s) founded in the specified SPECS.
[in] | pSPECS | SPECS where to get the information about the master card(s). |
[out] | pMasterCardsPCIList | list containing the PCI number of the master cards(s) founded. |
[out] | pMasterCardsDateList | list containing the PROM date of the master cards(s) founded. |
false error found.
(...) dyn_int myPCIList; dyn_dyn_int myDateList; int i; if (fwSpecs_getMasterCardsInfo("pclbcecs03", myPCIList, myDateList)) // get a list with information about the master card(s) of 'pclbcecs03' { DebugTN("Master card(s) founded: " + dynlen(myPCIList)); // display number of master card(s) founded for(i = 1; i <= dynlen(myPCIList); i++) { DebugTN("PCI number: " + (string) myPCIList[i]); // display PCI number where the master card is installed DebugTN("PROM date : " + (string) myDateList[i][1] + " (month), " + (string) myDateList[i][2] + " (day)"); // display master card PROM date } } else DebugTN("Error found!"); (...)
bool fwSpecs_getMasterIDs | ( | string | pSPECS, | |
dyn_int & | pMasterIDsList | |||
) |
This function returns the list of master IDs that have been found in the specified SPECS. If there is no master IDs, then the returned list will be empty.
[in] | pSPECS | SPECS where to get the master IDs. |
[out] | pMasterIDsList | list containing the master IDs. |
false error found.
(...) dyn_int myList; int i; if (fwSpecs_getMasterIDs("pclbcecs03", myList)) // get a list of master IDs existing in 'pclbcecs03' { DebugTN("Master IDs found: " + dynlen(myList)); // display number of master IDs found for(i = 1; i <= dynlen(myList); i++) DebugTN(myList[i]); } else DebugTN("Error found!"); (...)
bool fwSpecs_getRegisters | ( | dyn_dyn_string & | pRegistersList, | |
int | pRegisterType = -1 | |||
) |
This function returns a list containing registers of type I2C, PBUS, REG or DCU (or all).
[out] | pRegistersList | list containing the existing registers (with their respective settings) of a certain type. |
[in] | pRegisterType | type of the registers to be returned. These types are represented by the constants FWSPECS_I2C, FWSPECS_PBUS, FWSPECS_REG, and FWSPECS_DCU. Note: this parameter is optional (if not specified, then all registers will be returned without regarding their types). |
false error found.
(...) dyn_dyn_string myList; int i; if (fwSpecs_getRegisters(myList, FWSPECS_I2C)) // get a list of the existing I2C registers { DebugTN("Existing I2C registers: " + dynlen(myList)); // display number of existing I2C registers for(i = 1; i <= dynlen(myList); i++) { DebugTN("Register: " + myList[i][1]); // display I2C register name DebugTN("Settings: " + myList[i][2]); // display I2C register settings } } else DebugTN("Error found!"); (...)
bool fwSpecs_getScripts | ( | dyn_dyn_string & | pScriptsList | ) |
Get a list with the existing scripts.
[out] | pScriptsList | returned list containing the scripts. |
false error found.
(...) dyn_dyn_string myList; int i; if (fwSpecs_getScripts(myList)) // get a list of the existing scripts { DebugTN("Existing scripts: " + dynlen(myList)); // display number of existing scripts for(i = 1; i <= dynlen(myList); i++) { DebugTN("Name : " + myList[i][1]); // display script name DebugTN("Script: " + myList[i][2]); // display script } } else DebugTN("Error found!"); (...)
bool fwSpecs_remove | ( | string | pSPECS | ) |
This function removes the specified SPECS and, also, unsubscribes all the DIM services & commands associated with that SPECS.
[in] | pSPECS | name of the SPECS to be removed. |
false error found.
(...) if (fwSpecs_remove("pclbcecs03")) // remove the SPECS 'pclbcecs03' (...) else DebugTN("Error found!"); (...)
bool fwSpecs_removeRegisters | ( | dyn_string | pRegistersList | ) |
Remove (delete) a set of registers.
[in] | pRegistersList | list containing the registers to be removed (deleted). Note: if the register is being used for monitoring, the monitoring will be stopped before removing the register. |
false error found.
(...) if (fwSpecs_removeRegisters(makeDynString("myReg01", "myReg02"))) // remove (delete) the registers 'myReg01' and 'myReg02' (...) else DebugTN("Error found!"); (...)
bool fwSpecs_removeScript | ( | string | pScriptName | ) |
Remove the specified script.
[in] | pScriptName | name of the script to be removed. |
false error found.
(...) if (fwSpecs_removeScript("myScript")) // remove the script named 'myScript' (...) else DebugTN("Error found!"); (...)
int fwSpecs_resetMaster | ( | string | pSPECS, | |
int | pMasterID, | |||
int | hardResetFlag = 0 | |||
) |
This function resets a master ID located in the specified SPECS.
[in] | pSPECS | SPECS where the master ID is located. |
[in] | pMasterID | master ID to be reset. |
[in] | hardResetFlag | (optional). 0 = Soft Reset (default), 1 = Hard Reset. |
> 0 error found (related with SpecsUser; see error codes).
= -1 error found (related with PVSS).
(...) if (fwSpecs_resetMaster("pclbcecs03", 1) == 0) // reset master ID '1' from 'pclbcecs03' (...) else DebugTN("Error found!"); (...)
int fwSpecs_resetSlave | ( | string | pSPECS, | |
int | pMasterID, | |||
int | pSlaveAddress, | |||
int | pMode | |||
) |
This function resets a slave in a internal or external (equivalent to press the reset button of the mezzanine) mode located in the specified SPECS.
[in] | pSPECS | SPECS where the slave is located. |
[in] | pMasterID | master ID of the slave to be reset. |
[in] | pSlaveAddress | address of the slave to be reset. |
[in] | pMode | reset mode (FWSPECS_SLAVE_RESET_INTERNAL for internal mode, FWSPECS_SLAVE_RESET_EXTERNAL for external mode ot FWSPECS_SLAVE_RESET_EXTERNAL_SHORT for external mode short pulse). |
> 0 error found (related with SpecsUser; see error codes).
= -1 error found (related with PVSS).
(...) if (fwSpecs_resetSlave("pclbcecs03", 1, 2, FWSPECS_SLAVE_RESET_INTERNAL) == 0) // reset slave (internal mode) located (...) // in 'pclbcecs03', on master ID '1' and address '2' else DebugTN("Error found!"); (...)
bool fwSpecs_saveScript | ( | string | pScriptName, | |
string | pScript = "" | |||
) |
Create and save the specified script.
[in] | pScriptName | name of the script. |
[in] | pScript | the script to be saved. Note: this parameter is optional (if not specified, then an empty script will be saved). |
false error found.
(...) if (fwSpecs_saveScript("myScript", "main()\n {\n DebugTN(1);\n }\n")) // save the script under the name 'myScript' (...) else DebugTN("Error found!"); (...)
bool fwSpecs_setClockFrequency | ( | string | pSPECS, | |
int | pMasterID, | |||
int | pClockFrequency | |||
) |
This function sets a master ID to the specified clock frequency.
[in] | pSPECS | SPECS where the master ID is located. |
[in] | pMasterID | master ID to set the new clock frequency. |
[in] | pClockFrequency | new clock frequency (16 Khz, 32 Khz, 64 Khz, 128 Khz, 256 Khz, 512 Khz or 1024 KHz). Note: these frequencies are represented by the constants FWSPECS_CLOCK_16, FWSPECS_CLOCK_32, FWSPECS_CLOCK_64, FWSPECS_CLOCK_128, FWSPECS_CLOCK_256, FWSPECS_CLOCK_512 and FWSPECS_CLOCK_1024. |
false error found.
(...) if (fwSpecs_setClockFrequency("pclbcecs03", 1, FWSPECS_CLOCK_512)) // set the master ID '1' (located in 'pclbcecs03') to a clock frequency of 512 KHz DebugTN("Clock frequency set to 512 KHz!"); else DebugTN("Error found!"); (...)
int fwSpecs_slaveLeds | ( | string | pSPECS, | |
int | pMasterID, | |||
int | pSlaveAddress, | |||
int | pMode | |||
) |
This function turns the leds of the slave (mezzanine) ON/OFF.
[in] | pSPECS | SPECS where the slave is located. |
[in] | pMasterID | master ID of the slave to turn the leds ON/OFF. |
[in] | pSlaveAddress | address of the slave to turn the leds ON/OFF. |
[in] | pMode | turn the leds ON/OFF (FWSPECS_SLAVE_LEDS_ON to turn the leds ON or FWSPECS_SLAVE_LEDS_OFF to turn the leds OFF). |
> 0 error found (related with SpecsUser; see error codes).
= -1 error found (related with PVSS).
(...) if (fwSpecs_slaveLeds("pclbcecs03", 1, 2, FWSPECS_SLAVE_LEDS_ON) == 0) // turn the leds ON of the slave (mezzanine) located (...) // in 'pclbcecs03', on master ID '1' and address '2' else DebugTN("Error found!"); (...)